CPN Enclosure M2M Battery Backup Cooling

 

CPN Enclosure M2M Battery Backup Cooling

The CPN Enclosure M2M with Cooling and Battery Backup includes a Hughes 9502 two piece terminal that provides reliable IP connectivity over the Inmarsat Broadband Global Area Network (BGAN) and an Moxa Serial Device Server (RTU). A 30-Watt Cooling System is attached to the Enclosure to protect the complete System in hot whether conditions.

The system also includes in addition an industrial power supply and an powerful Batter Backup to protect the system against external power failures. The transmission of the data will be ensured for a limited time, even when the external power source is interrupted at the unmanned site.

 
 

please login to see prices


The CPN Enclosure M2M with Cooling and Battery Backup is a ready to install solution to connect the sensors or data loggers directly to the serial port of the RTU for SCADA and machine-to-machine (M2M) and IoT applications such as:

  • Mining, Oil and gas
  • pipeline monitoring/control
  • well site automation and surveillance
  • environmental monitoring
  • SmartGrid

The CPN Enclosure M2M with Cooling and Battery Backup is a cost-effective, always-on, real-time, high-speed M2M terminal for hot climate zones with:

  • Thermoelectric cooling unit 30-Watt / 12 VDC
  • Including a 120 / 240V AC/DC industrial power supply
  • Battery Backup
  • Moxa Serial Device Server (RTU)
  • IP 66 protected for installations in harsh environments
  • Easy to install

Special BGAN M2M Service plans that dramatically lowers monthly cost are available.

  • Dimensions: 465mm x 445mm x 160mm
  • Dust and Water: IP-66 protection class
  • Input Voltage power supply: 120 / 240V AC
  • Output Voltage power supply: 24V DC (18-29.5 V DC)
  • Output current power supply: 5A at 24V
  • Input voltage UPS: 24V DC
  • Output Voltage UPS (normal mode): 24V DC and 12V DC
  • Operating temperature: 0°C to +65°C
  • TÜV Certificate / CB Report on request
  • Interfaces:
    • 1 x 10/100 Mbps Ethernet (RJ-45)
    • 2 x Serial (1 x RS-232, 1 x RS-422/485)
    Version specific components
    • Power Supply
    • Uninterrupted Power Supply
    • Serial Device Server
    • 30W Peltier Cooling Device
    • Thermostat
    General components
    • Enclosure - standard color white
    • 2 pcs Myers Hub for external wiring of costumer equipment and power
    • Fused Terminal Block on the AC Line
    • Aluminum mounting plate inside w/DIN rail
    • Electrical grounding, central grounding point
    • Circuit breaker
    • Inside cabling
  • Antenna Cable Hughes 9502 M2M
    • 10m, 25m
  • Wall-mount, incl. mounting kit
  • Earth Stud (price on request)
  • External hinges (price on request)
  • Tamper-proof screws (price on request)